REVO III Hybrid Energy Storage Inverter

24v100AH (LS24100) & 24v150AH (LS24150)

12v100AH (LS12100)

REVO III Hybrid Energy Storage Inverter

5.5-8KW

Product Snapshot

  • Dimensions: 500X302X147.5
  • Model:5.5-8KW
  • Nominal Voltage: 230VAC
  • Frequency Range: 50Hz/60Hz

APPLICATIONS

  • Detachable touch screen control module with various communications(can be set)
  • PV and utility power the load at the same time
  • Output power factor PF=1.0. Energy generated record, load record, history information and fault record.
  • Support Peak – Valley Charge
  • Paraller operation up to 6 units.
  • Built-in two 5000W MPPTs, with wide input range: 120-450VDC
  • Reserved communication ports(RS232, RS458,CAN)

12V 24v LiFeP04 Deep Cycle Battery

MODEL REVO III 5500 REVO III 5500-P REVO III 8000
Rated Power 5500VA/5500W 5000VA/5000W 8000VA/8000W
INPUT
Voltage 230 VAC
Selectable Voltage Range 170-280 VAC (For Personal Computers)
90-280 VAC (For Home Appliances)
Frequency Range 50 Hz/60 Hz (Auto sensing)
OUTPUT
AC Voltage Regulation (Batt. Mode) 230VAC ± 5%
Surge Power 11000VA 16000VA
Efficiency (Peak) Up to 93.5%
Transfer Time 10 ms (For Personal Computers)
20 ms (For Home Appliances)
Waveform Pure sine wave
BATTERY
Battery Voltage 48 VDC
Floating Charge Voltage 54 VDC
Overcharge Protection 63 VDC
SOLAR CHARGER & AC CHARGER
Solar Charger type MPPT
Maximum PV Array Open Circuit Voltage 500 VDC
Maximum PV Array Power 5500W 5000W*2 5000W*2
MPP Range @ Operating Voltage 120 ~ 450 VDC
Maxmum Solar Charge Current 100A 120A
t Maximum AC Charge Current 80A 120A
Maximum Charge Current 100A 120A
PHYSICAL
Dimension, D x W x H (mm) 500X302X147.5 420X561.6X152.4
Net Weight (kgs) 12.7 18 21
Communication Interface USB/RS232/
OPERATING ENVIRONMENT
Humidity 5% to 95% Relative Humidity (Non-condensing)
Operating Temperature -10°C to 50°C
Storage Temperature -15°C to 60°C

Installation

Tools:

Multi meter, Ampere meter, Insulated gloves, Screw driver, Cold press terminal plier, Other installation tools

Note:

  1. All wiring must be well-fastened to avoid
  2. Make sure that the polarity of PV and batteries connected to the product is
  3. Should install utility, battery and PV input breaker to ensure
  4. It is forbidden for inverter to share the same solar panel
  5. Battery and solar panel connections must be within the parameters of the
  6. Should install SPD on utility and PV input to protect the
  7. During the operation of the system, do not disconnect the
  8. In areas with large dust, regular cleaning is required to avoid too much dust affecting heat
  9. Inverter protection degree is
Scroll to Top